UKCCSRC Call 2 project data: Performance of Flow Meters with Dense Phase CO2 and CCS Recovery Streams
Fiscal metering could face several challenges during CO2 transport by pipelines due to the unusual physical properties of CO2 and CO2 mixtures. Coriolis flowmeters are an options to measure CO2 accurately in transport pipelines. However, the presence of impurities can affect the performance of the flowmeter. Therefore, the performance of a Coriolis flowmeter was evaluated using CO2 fluid with impurities in a mass flow-rig designed based on the gravimetric calibration in start / stop operations. In each test, the mass recorded by the Coriolis flowmeter was compared to the mass collected in the receiving facilities and measured using high accurate balance in order to obtain the relative deviation of the test. During the tests, in addition to the mass and volume flow rate, the operational pressure and temperature as well as velocity and density were recorded. The series of tests were conducted using different fluids, including: pure N2 (validation tests), pure CO2 (reference tests), pre-combustion mixture, post-combustion mixture, Oxyfuel-I mixture and Oxyfuel-II mixture. The recorded data as well as recorded and measured masses are available in the provided excel files for each investigated fluid. Grant number: UKCCSRC-C2-201
nonGeographicDataset
http://www.bgs.ac.uk/ukccs/accessions/index.html#item71550
function: download
http://dx.doi.org/10.5285/81ae6d10-8e06-4ba7-b596-ce1141527193
name: Digital Object Identifier (DOI)
function: download
http://data.bgs.ac.uk/id/dataHolding/13607033
eng
geoscientificInformation
publication
2008-06-01
UKCCS
Carbon capture and storage
NGDC Deposited Data
revision
2022
NERC_DDC
2015-08
2016-07
creation
2014-09
notApplicable
The excel datasheets were recorded directly during the tests with each fluid. The recorded data were including temperature, pressure, density, velocity, mass and volumetric flow rates. Also in the excel files, the measured mass by balance and recorded mass by Coriolis meter as well as calculated relative deviations of each test are available. UKCCSRC Call 2 project, grant number: UKCCSRC-C2-201, Lead institution: Heriot-Watt University
publication
2011
false
See the referenced specification
publication
2010-12-08
false
See http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2010:323:0011:0102:EN:PDF
.xlsx
The copyright of materials derived from the British Geological Survey's work is vested in the Natural Environment Research Council [NERC]. No part of this work may be reproduced or transmitted in any form or by any means, or stored in a retrieval system of any nature, without the prior permission of the copyright holder, via the BGS Intellectual Property Rights Manager. Use by customers of information provided by the BGS, is at the customer's own risk. In view of the disparate sources of information at BGS's disposal, including such material donated to BGS, that BGS accepts in good faith as being accurate, the Natural Environment Research Council (NERC) gives no warranty, expressed or implied, as to the quality or accuracy of the information supplied, or to the information's suitability for any use. NERC/BGS accepts no liability whatever in respect of loss, damage, injury or other occurence however caused.
Heriot-Watt University
pointOfContact
Heriot-Watt University
principalInvestigator
British Geological Survey
The Lyell Centre, Research Avenue South
EDINBURGH
EH14 4AP
United Kingdom
+44 131 667 1000
pointOfContact
2025-03-24